Installation Instructions For John Sterling 1170 Series Heavy Duty Fall Prevention and Home Security Guards |
||||
|
For swing-open mounting: 1. Mount locking channel on right hand side of window: Drill 5/32" or 11/64" hole 3" deep for top screw only. Hang channel loosely on top screw, drill remaining holes and mount. 2. Hang right side of bars in locking channel. Hold hinge channel against left side of window, make sure guard is level, mark and drill top hole. Insert screw, drill remaining holes and drive screws. Note: Install only in solid, non-rotting window tracks. Expand guard to fit tightly into outside window track. Make sure guard is in level position NO MORE THAN 4-1/2 inches from sill to upper half of bottom bar.
Installation Tips
Surface Mount or Recess Mount? ![]()
Screws must project into wall studs for maximum security. In most cases, surface mounted Burglar Bars are easier to install because the screws are easier to drive. Surface mounting also makes screws more difficult to work on from outside the house by a potential intruder who might break the window and attempt to remove the screws.
|
||||
Safety Notes
|