Ask Barbara
|
|
|
|
Need advice on home safety? Ask our president
|
|
|
|
|
|
|
Q: Which System Does the DuoCare Monitor Follow? |
|
|
|
|
|
|
|
 |
|  | Focus on your home and safety. Take time to take the following safety quiz: For people suffering from asthmatic symptoms:
Q: How much do you know about the dangers of odors in confined spaces? To know answer
click here.. |
|  |  |
| Safe-T-Alert 40-411 Combustible Gas Detector | |
| Safe-T-Alert 40-411: Propane Gas Detector & Methane Gas Detector | |
MADE IN THE USA
Please Remember:
Gas detectors sense ONLY uncombusted gas. They provide NO protection against Carbon
Monoxide which is produced as a by-product of incomplete combustion of fossil fuels.
Click here for the companion CO detector.
Safe-T-Alert's 40-411 Dual Liquid Propane Gas (LP) and Natural Gas (Methane)
Detector was developed to provide protection from hidden gas leaks that can explode
with a spark. The Safe-T-Alert Propane Methane Detector should be located near sources
of a potential gas leak. For example, install the detector near a water heater,
furnace, or stove/oven that is heated by natural gas, propane gas, or methane gas.
Unlike some combustible gas detectors, this unit does NOT V.directly plug into a
wall outlet. The 65 inch cord permits proper mounting near the source of gas for
more accurate detection.
Propane gas is heavier than air. The detector should be mounted within 4 to 20 inches
of the floor to protect against propane gas leaks.
Methane gas (natural gas) is lighter than air. Mount the detector within 6 inches
from the ceiling or on the ceiling at least 12 inches from a wall.
The STA-40-411 uses the latest microprocessor technology. The Underwriters Laboratories
tests approved residential/RV usage only for Propane Gas and Methane Gas. This unit
also detects acetone, alcohol, butane, and gasoline, all of which be present in
your home.
Caution: Places where the gas alarm should NOT be installed:
-
DO NOT install behind furniture, drapes, in closets or in areas that will block
airflow to the detector.
-
DO NOT install within 12 inches of exterior doors, windows, heating or cooling return
cents, or other drafty areas or corners.
-
DO NOT install in or on outside walls or within 12 inches of corners.
-
DO NOT connect to a wall switch controlled power outlet or to a ground fault circuit.
Units require minimal maintenance. Test the circuit weekly. Test by pushing test
switch. The alarm will sound and the LED will flash red.
If an alarm sounds:
-
Turn off all gas appliances; extinguish all flames and smoking materials. Evacuate,
leaving doors and windows open.
-
Turn off the propane tank/ central natural gas valve.
-
Determine and repair the source of the leak. Seek professional help if necessary.
Caution:
-
This unit requires power.
-
This unit indicates presence of propane or methane gas ONLY at the sensor. Explosive
gas may be present in other areas.
-
This detector may not be heard. If mounted in a remote location, behind closed doors,
or in a home with a person with hearing impairment,the alarm may not be heard.
|
Features
|
Description
|
|
InteleCheck Circuit |
Eliminates false alarms from momentary exposure to Propane Gas, Natural Gas, aerosol
cleaners, hair spray and other flammable gases. An 8 second double-check circuit
is used to distinguish a gas leak from a momentary gas exposure.
|
|
Long Life, Self Cleaning Sensor |
Maintenance free built-in sensor. Sensor is tripped at less then 25% of the
lower explosive limit for natural gas, propane gas, and butane. |
|
Loud 85dB Alarm |
Alerts for presence of a potentially dangerous gas leak. |
|
Test/Reset Button |
Will temporarily silence alarm during ventilation. Tests all detector functions
with one touch. No Dangerous Gas Required. |
|
Warranty |
5 Year Limited Warranty |
|
Installation |
Attaches to wall with two screws. "Plug-it-in" installation |
|
Micro Current Technology |
Wall Transformer (120VAC to 12VDC) consumes only 3.8 watts of energy. I.E., only
33 Kwh per year costs less than US $3.00 per year to operate.
|
|
Power Alternatives |
RV Models are available which operate on 12V DC.
|
|
Operational Temperature Range |
-31°F to +150°F (-35°C to +66°C). |
|
Operating Relative Humidity Range |
15% to 93% |
|
Approval |
UL Listed as a "Single Station Propane/Methane Detector" to 1484 requirements. A
Propane Gas / Natural Gas Alarms for Residential and Unconditioned Area Use. UL
file number 151449. Use homes, and 'unconditioned' areas such as garages, boiler/furnace
rooms, warehouses, barns, offices, etc.
|
|
Mute Circuit |
Silence the alarm temporarily for two minutes. For added safety the Red LED will
continue to flash and the alarm will beep every 30 seconds until the gas has cleared.
|
|
Re-Alarm During Mute |
If gas re-enters the area during the Mute cycle, the detector sounds the alarm 4
times and the red LED will signal an new alarm condition.
|
|
Safe-T-Lock Malfunction Circuit |
If a malfunction occurs, the detector flashes an alternating Red/Green visual signal
and sounds once every 15 seconds. A malfunction cannot be over ridden by the Mute
switch. This operating feature gives an immediate identification of the type of
alarm and assists service and response personnel.
|
|
Test Circuit |
Press test switch for a complete diagnostic test in an instant. No gas is required. |
|
Detector Case Dimensions |
5.5"W x 3"H x 1.4"D |
| Buy Safe-T-Alert 40-411Combustible Gas Detector | |
| SM-STA-40-411-120 |
Safe-T-Alert Propane Natural Gas Alarm, 120V
Currently In Stock (11/22/2008)
|
US$49.95
|
Note: These 230VAC units were made especially for Safe Home Products' international
customers. The unit itself may be labeled 120VAC. Disregard this label if it has
the two pin round "German style" plug and 230VAC transformer. The base unit for
the 40-411A is a 12 VDC RV unit. The line cord with transformer modifies it for
AC usage.
Features two pin round "German style" plug. With a country specific plug modifier,
this 230VAC unit can be used in all countries with 230VAC power. These countries
include European, Asian, and African countries and some South American countries.
|
| SM-STA-40-411-230 |
Safe-T-Alert Propane & Natural Gas Alarm 240V (Non-USA)
Currently In Stock (11/22/2008)
|
US$59.95
|
|
|
|
| |